IEC61000 Test Systems

In order to test harmonics and flicker both a stable source, capable of simulating dips and interrupts, and a precise impedance network is required.

The interaction between the source’s own output impedance, the standalone impedance network make this difficult to setup. Our systems have been designed to work together in a compliant system and to produce the require reports.

System Overview

Description of the image

Key Components

Test Configurations

See below for the recommended test configurations

Calibration Comparison

3kVA System 6 kVA System 18 kVA System 30 kVA System 67 kVA System
Specification
Power (VA) 3kVA 6 kVA 18 kVA 30 kVA 67 kVA
Current Output (per Phase) 10Arms 20Arms 20Arms 32Arms 75Arms
Phases 1 1 3 3 3
Components
Power Analyzer PPA5511 PPA5511 PPA5531 PPA5531 PPA5531
Impedance Network IMP161 IMP162 IMP163 IMP323 IMP753
Calibration UKAS (optional) UKAS (optional) UKAS (optional) UKAS (optional) UKAS (optional)
AC Source N4A03 N4A06 N4A18 N4A30 N4A67

Standards

IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12, IEC61000-4-11*, IEC61000-4-13, IEC61000-4-17, IEC61000-4-29

* 5μ second dip and interrupt with ACD-230-20-1 simulator